Radiant comfort brings the building surfaces, conditioned fresh air and controls into one coordinated design. Every layer has a distinct job.

Interior concept for a home with concealed radiant climate design
Interior concept illustration

HEAT EXCHANGE, RECONSIDERED

Start with
the room itself.

Water circulates through designed radiant surfaces. In heating mode, warm surfaces exchange heat with the room; in cooling mode, cooler surfaces absorb heat. Radiation and natural convection both contribute.

Cooling surfaces do not remove the moisture load. Ventilation and dehumidification need separate sizing and a coordinated operating strategy.

Cooling output also depends on available surface area, water and room conditions, finishes and the building load. Some projects need auxiliary terminals.

FIVE COORDINATED LAYERS

From plant
to personal comfort.

01

01 · Heating & cooling source

Select suitable plant or an available supply interface for the location, building loads, operating temperatures and local service arrangements.

02

02 · Water distribution

Plan hydraulic circuits, insulation, balancing, zoning, water quality and access for maintenance.

03

03 · Room surfaces & terminals

Match radiant surfaces or hydronic terminals to capacity, architecture, finishes, response time and room use.

04

04 · Ventilation & moisture

Size outside air and humidity treatment for the real building and occupancy. Coordinate air paths, drainage, filtration and acoustics.

05

05 · Sensing & control

Define zone logic, dew-point safeguards, sensor-fault responses, mode changes and commissioning evidence.

TWO VALID DESIGN PATHS

Choose the system
that fits the home.

Yanghe · Radiant comfort

Radiant heating and cooling with ventilation, humidity management and dew-point coordination. Particularly relevant when low direct draught and architectural integration are priorities.

Ningrun · Hydronic comfort

A water-based system using fan-coil terminals, fresh air and zone control. It may suit quicker response or some renovation constraints. Fan-coil systems move air and are not described as windless.

Equipment, output, noise and energy use are project-specific. A final specification follows calculations and site coordination.